Everflo 12V Pump Not Pumping (PE flashing on controller)

Pump is not working, bypas the pressure switch(PE)

CAUTION: With the pressure switch bypassed, the pump will not shut off  automatically


Replacement parts Click here


Step 1: check battery is charged

Step 2: Check wires are connected and secure

Step 3: Check the inline fuse

Step 4: Remove wires going into the top of the pump

Step 5: Connect two wire connectors together using (wire or paperclip)

Step 6: Turn on pump with pressure switch bypassed


ONCE YOUR HAVE COMPLETED THE TEST ABOVE

(check fuse + bypass pressure switch)

If your pump works? - Buy a new pressure switch


If your pump does not work? - Faulty Pump

Tools Required

  • Needle nose pliers
  • Positive Head screwdriver

Consumables required

  • Clean rags for drying parts

PPE required

  • Gloves
  • Eye protection
  • Keep a clean rags/cloths


Replacement parts

Why are we checking the fuse and bypassing the pressure switch?

Why?

To identify if the pressure switch is faulty


Why?

Because if  the pressure switch is faulty, it can be bypassed to allow us to continue working until we get chance to replace the pressure switch


Why?

Replacing the pressure switch is cheaper than replacing the pump.


CAUTION: With the pressure switch bypassed, the pump will not shut off

If you're lucky enough to have a controller fitted to your system. 


The Big Brain IQ Controller is reading the status of the pump letting you know the pressure switch is activated. 


This lets you know you have power to your pump.


But the pressure switch is activated (likely a faulty pressure switch)